GB OPERATION
52
SPLIT
T1
T2
T3
T4
T5
T6
T7
T1 : +
T2 : On/O motor
T3 : -
T4: On/O light
T5:Tunable White e Dimmable light
fn: function
T6: O general
T7:Timer
Notes: this remote control is universal but not all features are available on all models.
ON FIRST USE OR IN THE EVENT OF NEEDING TO CHANGE THE REMOTE CONTROL OR THE PRODUCT’S ELECTRONIC
COMPONENTS, THE PAIRING PROCEDURE BETWEEN REMOTE CONTROL AND HOOD MUST BE PERFORMED (Valid for
all models):
1. Power o the hood for at least 10 seconds
2. Power on the hood again
3. Within the rst 5 sec press the lights button T4 and release after the lights have turned on
4. Within the next 5 sec press the motor button T2 and release it when the lights turn o
Now you need to wait approximately 10 seconds, after which you may use the hood normally.
SHOULD THERE BE ANY MALFUNCTIONS DUE TO INTERFERENCES WITH OTHER REMOTE CONTROLS NEARBY, PERFORM
THE PROCEDURE TO CHANGE THE REMOTE CONTROL’S TRANSMISSION CODE (Valid for all models)
The remote control is supplied with default codes. Should you wish to generate new random codes, the following procedure
must be performed: press simultaneously the two buttons plus T1 and minus T3 for at least 10 seconds. After the remote
control’s code has been changed, the pairing procedure must be performed.
Button T2 (On/O motor): pressing the T2 button turns the motor on or o, acting on the T1(+) or T3 (-) buttons increases or
decreases the speed
1° Speed: Green LED
2° Speed: Flashing green LED
3° Speed: Orange LED
4° Speed: Flashing orange LED
5° Speed: Red LED
6° Speed: ashing red LED (intensive timed for 8 minutes, after which it returns to 5 speed)
Button T4 :On/O light (LED bar).
Light panel: when the fn and T4 keys are simultaneously pressed, panel light is On/O
Only for models with the Tunable White and Dimmable light feature
Press the button T5 to enter the Dimmable light function LED ashes green quickly (changing light intensity with the +/-
buttons).
Press the button T5 again to enter the Tunable White function LED ashes orange quickly (changing light colour with the
+/- buttons).
Press T5 again to exit the menu
N.B. In any case, after 10 sec of inactivity the remote control automatically exits the menu.
Button T6 (O general): if the button is pressed for a long time, both the lights and the motor turn o.
Button T7 (timer) : with the motor running, pressing the T7 button activates the timer function lasting 5 minutes, indicated by
the LED ashing red-green at the end of 5 minutes the motor switches o.