Updating Firmware Through IXG Support Tool
This method will work for both IXG and IX Series stations. Use the links on the page 18 to download the required
rmware updates. These will be downloaded in a compressed folder. Use the programming PC's built-in methods
to extract the rmware update, which is stored as a .bin le.
Navigate to Maintenance, Firmware Update. The page will display a menu showing di󰀨erent station types. Use
the
Browse
buttons to navigate to where the appropriate rmware .bin le is located. Multiple station types can
have a rmware update selected at a time.
Select all of the stations to be updated and click
Update
. This process will take several minutes, and the stations
will reboot during this time. Stations with a screen will display a status bar during the update. All stations will show
a solid status light once the process is complete.
Do not interrupt a rmware
update once it has started,
including unplugging the
station. Doing so can
damage the station.
In order to update the
Sub Firmware on an
IXG-DM7-*, the Wiegand
connection on the card
reader needs to be
connected to an access
control system for power.