SYSTEM PROGRAMMING WITH MULTIPLE GT-MCX: MULTI-BUILDING (cont.)
Step 5: Select the rst MCX in the system, then click Section Info. Enter a Section #, a Section Name, and
IP Address for each GT-MCX in the system based on what was selected in Step 3. Ensure that tenant
sections are entered in lines 1-24 and Main Sections are entered in lines 25-32. Click Save
when done.
Step 6: Repeat step 5 for each MCX in the system. Copy/Paste (Ctrl C, Ctrl V) from the rst MCX Section Info to
other sections can be used to save time.
Step 1: Create an ID correlation table for the tenant stations using the binary / SW2 Dip Switch - ID chart.
The chart below is for the rst 48 stations in a non-expanded or expanded system.
The full Dip Switch chart can be downloaded from https://www.aiphone.net/product/support/gt/
Standard system = S1 - S48. Expanded system = A1 - A250 & B251 - B500
Step 2:
Set the SW2 dip switches found on the back of the GT-1C7(-L), GT-1C7W(-L), GT-1M3(-L), and GT-2C(-L) according to
the correlation table created in the previous step.
S1 / A1
S2
/ A2
S3
/ A3
S4
/ A4
S5
/ A5
S6
/ A6
S7
/ A7
S8
/ A8
S9
/ A9
S10
/ A10
S11
/
A11
S12
/ A12
Dip Switch ID
S13 / A13
S14
/ A14
S15
/ A15
S16
/ A16
S17
/ A17
S18
/ A18
S19
/ A19
S20
/ A20
S21
/ A21
S22
/ A22
S23
/ A23
S24
/ A24
Dip Switch ID
S25 / A25
S26
/ A26
S27
/ A27
S28
/ A28
S29
/ A29
S30
/ A30
S31
/ A31
S32
/ A32
S33
/ A33
S34
/ A34
S35
/ A35
S36
/ A36
Dip Switch ID
S37 / A37
S38
/ A38
S39
/ A39
S40
/ A40
S41
/ A41
S42
/ A42
S43
/ A43
S44
/ A44
S45
/ A45
S46
/ A46
S47
/ A47
S48
/ A48
Dip Switch ID
On
O
128 64 32 16 8 4 2 1
SW2
PROGRAMMING: ADDRESSING TENANTS VIA DIP SWITCH METHOD
Note: If programming a multi-building system with more than 500 tenants, ensure that the Calling Method is set to
either Section List + Unit#, Section# + Unit#, or Unit Number in the Main Section.
If updating dimensions, be sure to update the GLC layer too.
Please refer to the Product Dimensions Master located here:
H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx
JO-1MDW
JO-1MDW
8-1/4" 1-1/16"
6-1/8"
GT-1C7W(-L)
GT-2C(-L)GT-1M3(-L)GT-1C7(-L)
Bekijk gratis de handleiding van Aiphone GT-OP3, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Aiphone |
Model | GT-OP3 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 7519 MB |