Aiphone GT-203HB handleiding
Handleiding
Je bekijkt pagina 38 van 52

- 38 -
IN
C
CE
OUT
R1
R2
R1
R2
KKE
IN
C
CE
OUT
KKE
R1
R2
R1
R2
GT-BC
DP
1P
NP
1P
NP
NP
NP
Residential/tenant station (audio only)
GT-1A
GT-1A
GT-1A
* Connect to the audio bus control
unit.
Standard system: section
4-1
Expanded system: section
4-5
(No connection is needed to the
video bus control unit GT-VBC.)
NP: Non-polarized
NOTE: Refer to section
4-7
for details about wiring to the option connector.
Emergency alarm switch
(*2)
(GFK-PS available in North America only.)
Doorbell
(*1)
(third party product)
(*3)
(*1): Doorbell
• N/O contact (non-locked type)
• DC 12 V/0.1 A or higher
(*2): Emergency alarm switch
• N/C contact (locked type)
• DC 12 V/0.1 A or higher
(*3): Jumper wiring between
K
and
KE
.
Jumper wire must remain in place if not using an
emergency alarm switch.