*DP
CN1
CN1
CN100
CN100
CN2
CN2
ELC
ELM
ELB
PT
R1
R2
+
-
+
-
PS24
+
-
ELC
ELM
ELB
PT
A1 A2R1 R2
A1
A2
PS-2420UL
GT-BCGT-VBC
PS-2420UL PS-2420UL
1P
1P1P
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P
1P x 2
1P x 2
1P x 2
1P x 2
GT-4Z
GT-4Z
Doorbell
1P
GFK-PS
GT-1C
GT-1C
1P x 2
1P x 2
Trunk Line No. 1
Homerun using
GT-4Z (max. 6)
Trunk Line No. 2
Loop wiring
(max. 25)
Trunk Line
No. 3-6
GT-MK w/
GFW-S
GT-MK w/
GFW-S
Security Guard/Concierge Stations (max. 2)Entrance Stations (max. 5)
NOTE: Do not mix loop and
homerun wiring methods
on the same trunk.
GT Standard Configuration Sample
R1
R2
+
-
+
-
PS24
GT-BC
+
-
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
Max. of 25 stations
per loop. SW1 switch
must be set to A on last
station in the wire loop.
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2B1 B2R1R2
B1 B2R1R2
Max. of 6 GT-4Zs per trunk. SW1 switch must be
set to A on last GT-4Z in the wire trunk. Each tenant
station homeruns to a GT-4Z and its SW1 switch
must be set to A.
GT-VBC
B1 B2R1R2 B1 B2
R1R2
B1 B2R1R2 B1 B2R1R2 B1 B2R1R2
R1R2B1 B2
OUT (1) OUT (2)
OUT (3) OUT (4)
IN
LINE OUT
SW1
A
B
GT-4Z
B1 B2R1R2 B1 B2R1R2
B1 B2R1R2 B1 B2R1R2 B1 B2R1R2
R1R2B1 B2
OUT (1) OUT (2)
OUT (3) OUT (4)
IN
LINE OUT
SW1
A
B
GT-4Z
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
IN
IN
IN
IN
IN
IN
IN
Loop Wiring Method Homerun Wiring Method
Tenant stations shown are the
GT-1C7(-L). The GT-1M3(-L),
GT-2C(-L), and GT-1C7W(-L)
tenant stations can also be used
and wired in the same manner.
Note: GT-2C(-L) and GT-1C7W(-L)
require a separate PS-24 power
supply.
Mag
Lock
Door
Strike
STANDARD SYSTEM WIRING: AUDIO / VIDEO
R1
R1
R2
R2
A
B
A
B
A
B
SW1
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
4 | GT Series Quick Start Guide
To additional units
**
**
SW1
T-Tap Wiring Method
Max. of 25 stations
per trunk with GT-1Z.
SW1 switch must
be set to A on each
tenant station.
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
A
B
A
B
A
B
SW1
GT-1ZGT-1ZGT-1Z
LINE IN LINE IN LINE INLINE OUT LINE OUT LINE OUT
To
Additional
units
OUT
OUT
OUT
IN
IN
IN
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
ELM: Make (N/O)
ELC: Common
ELB: Break (N/C)
*
Distribution Point:
(GTW-DP) Available in
North America. (GFC)
Available in Europe. This
can be any device that
parallels or commons
the R1 / R2 connection.
(Terminal strip, punch
down block, wire nuts, etc.)
Use Sxx (S1-S48) for link ID settings for
addressing tenants via dip switch method in a
standard system (refer to page 8 for settings).
+
-
GT-MKB-N
+
-
PS24
ON
1 2 3
4
#1
IN
IN
R1
R2
B1
B2

Bekijk gratis de handleiding van Aiphone GF-2P, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAiphone
ModelGF-2P
CategorieNiet gecategoriseerd
TaalNederlands
Grootte7519 MB

Caratteristiche Prodotto

Kleur van het productZink
MateriaalZink
Aantal per verpakking1 stuk(s)
MerkcompatibiliteitAiphone
Type productToegangsbesturingseenheid