11.10 Cleaning the inlet hose and
the valve filter
It is recommended to clean both the filters of
the inlet hose and valve twice a year to
remove any deposit, collected over the time.
Proceed as described in following diagrams
to clean filters:
1. Remove the inlet hose from the tap and
clean the filter.
1
2
3
2. Remove the inlet hose from the appliance
by loosening the ring nut.
3. Clean the valve filter on the back of the
appliance with a toothbrush.
4. When you reconnect the hose to the back
of the appliance, turn it left or right (not in
vertical position) depending on the
position of your water tap.
45°
20°
11.11 Emergency drain
If the appliance cannot drain the water, carry
out the same procedure, described in
'Cleaning the drain pump' paragraph. If
necessary, clean the pump.
11.12 Frost precautions
If the appliance is installed in an area where
the temperature can reach the values around
0° C or drop below, remove the remaining
water from the inlet hose and the drain pump.
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in a
container and let the water flow out of the
hose.
4. Empty the drain pump. Refer to the
emergency drain procedure.
5. When the drain pump is empty, install the
inlet hose again.