35
Manual service
EN
FREE STANDING INDUCTION
GLN MANETTE 2500 / 3000 / 3500
TECHNICAL
FEATURES
SECURITY AND PROBLEMS:
If you read on the keyboard a message ER.XX (with XX 01 to 19), see the follo-
wing table.
Display Key-
board error
Potenal causes Intervenon
ER.01 In vitro sensor in short circuit slave home AFTER SALES
ER.02 In vitro sensor cut o or absent slave home AFTER SALES
ER.03 Sensor in vitro short-circuit master focus AFTER SALES
ER.04 In vitro sensor cut o or absent master replace AFTER SALES
ER.05 IGBT sensor shorted AFTER SALES
ER.05 Sensor temperature generator card cut or missing AFTER SALES
ER.06 IGBT temperature sensor switched o or missing AFTER SALES
ER.06 Sensor temperature generator in short circuit AFTER SALES
ER.07 Temperature on IGBT too high Press on / o key to acknowledge fault, or dis-
ER.08 The temperature of the in vitro sensor does not vary
Press the on / o key to acknowledge the fault
or disconnect / reconnect product. If error code
sll present: Call Aer sales service.
ER.13 One or more fans missing or defecve
ER.14 One or more fans missing or defecve
ER.15 Measuring fault of the inducve current
ER.16 Failure to measure the phase of the inducve current
ER.18 Internal 13.8-volt generator voltage fault
ER.29 Analogue safety fault
ER.31 Slave generator communicaon fault
ER.09 Mains voltage below 85 Vac
ER.20 Mains frequency below 285 Hz
ER.10 Line voltage greater than 285 Vac
ER.19 Mains frequency greater than 70 Hz