UNO-430-E1H User Manual vi
20. For safe installation purpose, when installing this product, please pay attention
to the nearby area to see if there is a possibility of objects falling and hitting the
product, reducing the risk of mechanical danger.
21. Operators should wear electrostatic wrist or heel straps when they touch UNO-
430.
DISCLAIMER: These instructions are provided according to IEC 704-1 standards.
Advantech disclaims all responsibility for the accuracy of any statements contained
herein.
Safety Instructions (IECEx / ATEX)
1. The equipment shall only be used in areas with at least pollution degree 2, as
defined in IEC 60664-1.
2. Transient protection shall be provided that is set at a level not exceeding 140%
of the peak rated voltage at the supply terminals to the equipment.
3. The equipment was evaluated in low mechanical impact conditions. The devices
should be mounted in vertical position and installed in a low risk environment.
4. The enclosure has a non-metallic coating so installation/operation must mini-
mize the risk from electrostatic discharge. Operators should wear electrostatic
wrist or heel straps when they touch equipment.
Safety Instructions (C1D2 Only)
1. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or
non-hazardous locations only.
2. Ambient temperature range as indicated under “Environment Ratings”.
3. Temperature Class (T-Code): T4
4. WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT
WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE
FREE OF IGNITABLE CONENTRATIONS.
5. This equipment is intended to be mounted on a pole with the mounting bracket,
wall mounting or DIN mounting; the mounting should always let water proof con-
nectors down to bottom position.” or similar.
6. This equipment should be installed with suitable Listed conduits in accordance
with Article 501.10(B)(2) of the National Electrical Code (ANSI/NFPA 70). Suit-
ability for installation in particular applications is at the discretion of the Authority
Having Jurisdiction (AHJ).” or similar.
Field wiring, Earthing, Bonding information
1. The input terminal block (CN25) should be installed to 12-22AWG wires with 8
mm conductor insulation stripped.
2. The COM terminal blocks (CN18, CN19, CN20, CN21) should be installed to 14-
26AWG wire with 10 mm solid conductor insulation stripped.
3. The internal earth connection should be installed to a conductor equal to input
terminal block 12-22AWG.
4. The external bonding conductor should be installed to a conductor with at least
4 mm² cross-sectional area.
5. The field wiring cable should be rated ≥ 90°C.