This command writes from “1” to “256” sectors as specified in the Sector Count register using the DMA
data transfer protocol. A sector count of “0” requests “256” sectors transfer. The transfer begins at the
sector specified in the Sector Number register.
46. WRITR DMA EXT (code: 35h);
This command writes from “1” to “65536” sectors as specified in the Sector Count register using the DMA
data transfer protocol. A sector count of “0” requests “65536” sectors transfer. The transfer begins at the
sector specified in the Sector Number register.
47. WRITE MULTIPLE (code: C5h);
This command is similar to the WRITE SECTORS command. Interrupts are not presented on each sector,
but on the transfer of a block which contains the number of sectors defined by Set Multiple command.
48. WRITE MULTIPLE EXT (code: 39h);
This command is similar to the WRITE SECTORS command. Interrupts are not presented on each sector,
but on the transfer of a block which contains the number of sectors defined by Set Multiple command.
49. WRITE SECTOR(S) (code: 30h);
This command writes from “1” to “256” sectors as specified in the Sector Count register. A sector count of
“0” requests “256” sectors transfer. The transfer begins at the sector specified in the Sector Number
register.
50. WRITE SECTOR(S) EXT (code: 34h);
This command writes from “1” to “65536” sectors as specified in the Sector Count register. A sector count
of “0” requests “65536” sectors transfer. The transfer begins at the sector specified in the Sector Number
register.
51. WRITE SECTOR(S) W/O ERASE (code: 38h);
This command writes from “1” to “256” sectors as specified in the Sector Count register. A sector count of
“0” requests “256” sectors transfer. The transfer begins at the sector specified in the Sector Number
register.
52. WRITE VERIFY (code: 3Ch);
This command is similar to the WRITE SECTOR(S) command, except that each sector is verified before
the command is completed.

Bekijk gratis de handleiding van Advantech SQF-SLM 630, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAdvantech
ModelSQF-SLM 630
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3884 MB

Caratteristiche Prodotto

Breedte39 mm
Diepte4.5 mm
Hoogte54 mm
InterfaceSATA III
VeiligheidsfuntiesShock resistant, Vibration proof