23. SECURITY DISABLE PASSWORD (code: F6h);
This command transfers 512 bytes of data from the host. Table defines the content of this information. If
the password selected by word 0 match the password previously saved by the device, the device shall
disable the Lock mode. This command shall not change the Master password. The Master password
shall be reactivated when a User password is set.
24. SECURITY ERASE PREPARE (code: F3h);
This command shall be issued immediately before the SECURITY ERASE UNIT command to enable
device eraseing and unlocking.
25. SECURITY ERASE UNIT (code: F4h);
This command transfer 512 bytes of data from the host. Table## defines the content of this information. If
the password does not match the password previously saved by the device, the device shall reject the
command with command aborted.
The SECURITY ERASE PREPARE command shall be completed immediately prior to the SECURITY
ERASE UNIT command.
26. SECURITY FREEZE LOCK (code: F5h);
This command shall set the device to frozen mode. After command completion any other commands that
update the device Lock mode shall be command aborted. Frozen shall be disabled by power-off or
hardware reset.
If SECURITY FREEZE LOCK is issued when the drive is in frozen mode, the drive executes the
command and remains in frozen mode.
27. SECURITY SET PASSWORD (code: F1h);
This command transfer 512 bytes of data from the host. Table defines the content of this information. The
data transferred controls the function of this command. Table defines the interaction of the identifier and
security level bits.
28. SECURITY UNLOCK (code: F2h);
This command transfer 512 bytes of data from the host. Table (as Disable Password) defines the content
of this information.
If the Identifier bit is set to Master and the device is in high security level, then the password supplied
shall be compared with the stored Master password. If the device is in maximum security level then the
unlock shall be rejected.
If the identifier bit is set to user then the device shall compare the supplied password with the stored User
password.
If the password compare fails then the device shall return command aborted to the host and decrements
the unlock counter. This counter shall be initially set to five and shall be decremented for each password
mismatch when SECURITY UNLOCK is issued and the device is locked. When this counter reachs zero
then SECURITY UNLOCK and SECURITY ERASE UNIT command shall be aborted unitl a power-on or
a hardware reset.
29. SEEK (code: 7Xh);
This command performs address range check.
30. SET MAX ADDRESS (code: F9h);
After successful command completion, all read and write access attempts to address greater than
specified by the successful SET MAX ADDRESS command shall be rejected with an IDNF error.
IDENTIFY DEVICE response words (61:60) shall reflect the maximum address set with this command.
31. SET MAX ADDRESS EXT (code: 37h);
After successful command completion, all read and write access attempts to address greater than
specified by the successful SET MAX ADDRESS command shall be rejected with an IDNF error.
IDENTIFY DEVICE response words (61:60) shall reflect the maximum address set with this command.

Bekijk gratis de handleiding van Advantech SQF-SLM 630, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAdvantech
ModelSQF-SLM 630
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3884 MB

Caratteristiche Prodotto

Breedte39 mm
Diepte4.5 mm
Hoogte54 mm
InterfaceSATA III
VeiligheidsfuntiesShock resistant, Vibration proof