SKY-MXM-T1000 User Manual 10
2.1 Power Sequencing
There is no power sequencing requirement for the input voltages to the MXM mod-
ule. However the PWR_EN signal may be asserted only after all power rails are
within specified tolerances. The state of PWR_GOOD is undefined until all the rails
are fully ramped. Refer to Figure 2.1 for details.
Figure 2.1 Power Sequencing
Table 2.1: Signals Exempted
Group Signals
Power and Thermal SMB_CLK, SMB_DAT, TH_OVER#, TH_ALERT#, PWR_GOOD
System Management WAKE#, PEX_CLK_REQ#
Display DP_x_HPD, LVDS_x_HPD
Note! No voltage shall be applied to any MXM module signal pin (except
power pins and open drain signals specified in Table 2.1) until PWR_-
GOOD is asserted.