RSB-4410 User Manual 26
/dev/ttymxc0, UART: undefined, Port: 0x0000, IRQ: 58
/dev/ttymxc1, UART: undefined, Port: 0x0000, IRQ: 59
/dev/ttymxc3, UART: undefined, Port: 0x0000, IRQ: 61
/dev/ttymxc4, UART: undefined, Port: 0x0000, IRQ: 62
Below test was done with four 2.0mm pitch mini jumpers. Advantech P/N is
1653302122. This mini jumper is a bridge connecting Tx and Rx.
2.5.9.1 /dev/ttymxc1 testing (CN9)
#stty -F /dev/ttymxc1 -echo
#cat /dev/ttymxc1
[CTRL+Z]
#echo hello > /dev/ttymxc1
#fg
Hello
[CTRL+C]
2.5.9.2 /dev/ttymxc3 testing (CN10)
#stty -F /dev/ttymxc3 -echo
#cat /dev/ttymxc3
[CTRL+Z]
#echo hello > /dev/ttymxc3
#fg
Hello
[CTRL+C]
2.5.9.3 /dev/ttymxc4 testing (CN12)
#stty -F /dev/ttymxc4 -echo
#cat /dev/ttymxc4
[CTRL+Z]
#echo hello > /dev/ttymxc4
#fg
Hello
[CTRL+C]
2.5.10 Watchdog Timer Test
1. Executing‘ wdt_driver_test.out
#/unit_tests/wdt_driver_test.out
Usage: wdt_driver_test <timeout> <sleep> <test>
timeout: value in seconds to cause wdt timeout/reset
sleep: value in seconds to service the wdt
test: 0 - Service wdt with ioctl(), 1 - with write()
2. Please try below command to set timeout as 10 seconds, system will reboot
after then.
#/unit_tests/wdt_driver_test.out 10 5 0
Starting wdt_driver (timeout: 10, sleep: 5, test: ioctl)
Trying to set timeout value=10 seconds