59 Chapter 7
7.5 Counter Applications
The 8254 programmable Interval timer/counter on your PCM-3718 inter-
face module is a very useful device. You can program counters 1 and 2 as
pacers to generate A/D conversion trigger pulses.
Setting the Pacer Rate
The following equation gives the pacer rate:
Pacer rate = FCLK / (C1 *C2)
FCLK is either 1 MHz or 10 MHz, as set by jumper JP1. The following
steps tell you how to set the counter modes and constants:
1. Set Counter 1 to Mode 3 by writing ’76h’ to address BASE+15.
2. Set Counter 1’s divisor constant C1 by writing to BASE+13. Con-
stant C1 can be any 16-bit value from 2 to 65535. Because the 8254
has 8-bit registers, you should first write the low byte of C1 to
BASE+13, then write the high byte of C1 to BASE+13.
3. Set Counter 2 to Mode 3 by writing ‘B6h’ to address BASE+15.
4. Set Counter 2’s divisor constant C2 by writing to BASE+14. Con-
stant C2 can be any 16-bit value from 2 to 65535. Because the 8254
has 8-bit registers, you should first write the low byte of C2 to
BASE+14, then write the high byte of C2 to BASE+14.