Advantech PCI-1285 handleiding

247 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 247
15 PCI-1285/1285E User Manual
Chapter 3 Signal Connections
3.11 Emergency Stop Input (EMG)
When emergency stop input signal is enabled, the output of the drive pulse for all
axes will be stopped.
Figure 3.8 Circuit Diagram of Emergency Stop Input Signal
This signal should be used in combination with external power DC 12 ~ 24 V. The
response time of circuitry should take about 0.25 msec because of the delay of photo
coupled and RC filter.
3.12 External Power Input (VEX)
External power is necessary for all input signals of each axis. Apply DC 12 ~ 24 V
voltage as required.
3.13 Position Window Output [CAM-DO]
As the following figure shows, users can define the interval and level to generate a
digital output with a defined duration.
Figure 3.9 Circuit Diagram of Position Window Output
Note! Please don't direct connect VEX to inductive load.