Advantech PCI-1220U handleiding

56 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 56
19 Chapter 3
3.4 General Purposed Output
The general purposed output nOUT3/DSND, nOUT2/ASND, nOUT1/
CMPM, and nOUT0/CMPP are from MCX312, and each output signal is
OFF status after system reset.
Figure 3.6: General Purpose Output
General purposed output signals used in motor drives can clear error
counter, alarm reset, stimulus off, etc., or select acceleration/deceleration
for driving, position counter, and the status of comparison register as your
output during driving.
3.5 Over Traveling Limit Switch Input
Note: When the axis/axes is/are about to stop (in the decelera-
tion stage), the axis/axes will not stop totally but keep
moving at a very low speed if you use S-curve accelera-
tion/deceleration to control speed under the “Point to
Point” and “Line Profile(interpolation)” drive mode
(positioning operation, specify a target position) on the
conditions below:
The hardware limit is activated and the Limited Switch
Operation Mode is set to “Slow Down then Stop” (WR2/
D2=1).
The software limit is enabled and activated (WR3/D, 1=1).
The Limited Switch Function of IN1 and IN2 are
enabled (WR1/D5, 3, 1=1).