5.3 Downlink Commands
LEO-S595-WBG0 supports downlink commands to configure the device. The application port
is 85 by default.
Examples:
1. Set reporting interval as 20 minutes.
2. Reboot the device.
3. Disable double press mode.
-END-
ff 2e 01
Channel
Type
Value
ff
2e(Button Message)
01 => short press
Channe
l
Type
Description
ff
03 (Set Reporting Interval)
2 Bytes, unit: s
10 (Reboot)
ff (Reserved)
2f (Set LED Indicator)
00: Disable
01: Enable
74 (Set Double Press Mode)
00: Disable
01: Enable
3e (Set Buzzer)
00: Disable
01: Enable
ff03b004
Channel
Type
Value
ff
03 (Set Reporting
Interval)
b0 04 => 04 b0 = 1200s
= 20 minutes
ff10ff
Channel
Type
Value
ff
10 (Reboot)
ff (Reserved)
ff7400
Channel
Type
Value
ff
74 (Set Double Press)
00 => Disable