IDK-2112P User Manual 14
2.8 Power On/Off Sequence
The power sequence specifications are displayed in the following table and diagram.
Note (1) Please avoid interface signal floating states at invalid periods.
Note (2) When the interface signal is invalid, be sure to reduce the LCD VCC
power supply to 0 V.
Note (3) The backlight converter power must be turned on after the power supply
for the logic and the interface signal turns on. The backlight converter
power must be turned off before the power supply for the logic and the
interface signal turns off.
Table 2.8: Timing Specifications
Parameter
Value
Units
Min Typ Max
T1 0.5 - 10 ms
T2 0 - 50 ms
T3 0 - 50 ms
T4 500 - - ms
T5 450 - - ms
T6 200 - - ms
T7 10 - 100 ms
T8 10 - - ms
T9 10 - - ms
T10 20 - 50 ms