Advantech IDK-2112P-K2XGA1 handleiding

33 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 20 van 33
IDK-2112P User Manual 14
2.8 Power On/Off Sequence
The power sequence specifications are displayed in the following table and diagram.
Note (1) Please avoid interface signal floating states at invalid periods.
Note (2) When the interface signal is invalid, be sure to reduce the LCD VCC
power supply to 0 V.
Note (3) The backlight converter power must be turned on after the power supply
for the logic and the interface signal turns on. The backlight converter
power must be turned off before the power supply for the logic and the
interface signal turns off.
Table 2.8: Timing Specifications
Parameter
Value
Units
Min Typ Max
T1 0.5 - 10 ms
T2 0 - 50 ms
T3 0 - 50 ms
T4 500 - - ms
T5 450 - - ms
T6 200 - - ms
T7 10 - 100 ms
T8 10 - - ms
T9 10 - - ms
T10 20 - 50 ms

Bekijk gratis de handleiding van Advantech IDK-2112P-K2XGA1, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAdvantech
ModelIDK-2112P-K2XGA1
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3772 MB

Caratteristiche Prodotto

Gewicht980 g
Breedte279 mm
Diepte11.3 mm
Hoogte209 mm
Beeldschermdiagonaal12.1 "