IDK-1110R-50XGB1 User Manual 34
Note (5) Measurement Setup:
The LCD module should be stabilized at a given temperature to avoid
abrupt temperature change during measurement. In order to stabilize
the luminance, the measurement should be executed after lighting up
the backlight for 40 minutes in a windless room. The measurement
placement of the module should be in accordance with the module
drawing.
Note (6) Definition of White Variation (
W):
Measure the luminance of White at 5 points.
Luminance of White: L(X), where X is from 1 to 5.