There are various methods to connect to the serial console port.
For those utilizing Windows OS on their working PC, a commonly used tool is PuTTY. Follow the steps
below to establish a connection using PuTTY.
If you are not familiar with PuTTY or have not installed it yet, you can download it from
https://www.putty.org/ .
For users intending to use PuTTY on a PC running Windows OS, the subsequent section outlines how
to configure PuTTY on a Windows platform for connecting to the FWA-6172 serial console.
Feel free to skip these steps if you have another preferred method, as other terminal programs can
be used similarly.
Open PuTTY and initiate the configuration as detailed below. Instead of "COMx," use the actual COM
port number from your client machine. The "COMx" designation will vary based on what you observe
in your Windows Device Manager (refer to Figure 2.4-6).
In this guide, "COM1" is used as an example, as you might see it listed in the Device Manager.
Figure 2.4-4 Windows Device Management COM Number Example
A. Under "serial line", specify "COM1" and set the speed to "115200". Choose "no parity" and
"no flow control". The default baud rate for the COM port is 115200 with no parity and no
flow control.
B. If you have previously modified these settings, please use the baud rate you configured in
the BIOS; refer to the "Common BIOS User Manual (Section 1.2.2.1)." It's important to note
that the BIOS and OS may have different serial console configurations.