Space
A parity bit can be sent with the data bits to detect some transmission
errors. Even: parity
bit is 0 if the num of 1’s in the data bits is even. Odd: parity bit is 0 if num of 1’
s in the
data bits is odd. Mark: parity bit is always 1.Space:Parity bit is always 0.Mark and Space
Parity do not allow for error detection.
Stop Bits 1 Optimal Default, Failsafe Default
2
Stop bits indicate the end of a serial data packet.
(A start bit indicates the beginning).The
standard setting is 1 stop bit. Communication with slow devices may require more than 1
stop bit.
Flow Control None Optimal Default, Failsafe Default
Hardware RTS/CTS
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a 'stop' signal can be sent to stop the data flow. Once the buffers
are empty, a 'start' signal can be sent to re-start the flow. Hardw
are flow control uses two
wires to send start/stop signals.
VT-
UTF8 Combo Key
Support
Disabled
Enabled Optimal Default, Failsafe Default
Enable VT-UTF8 Combination Key Support for ANSI/VT100 terminals
Recorder Mode Disabled Optimal Default, Failsafe Default
Enabled
With this mode enabled only text will be sent. This is to capture Terminal data.
Resolution 100x31 Disabled Optimal Default, Failsafe Default
Enabled
Enables or disables extended terminal resolution
Legacy OS Redirection
Resolution
80x24 Optimal Default, Failsafe Default
80x25
On Legacy OS, the Number of Rows and Columns supported redirection
Putty KeyPad VT100 Optimal Default, Failsafe Default
LINUX
XTERMR6
SCO
ESCN
VT400
Select FunctionKey and KeyPad on Putty.
Redirection After BIOS
POST
Always Enable Optimal Default, Failsafe Default
BootLoader
The Settings specify if BootLoader
is selected then Legacy console redirection is disabled
before booting to Legacy OS. Default value is Always Enable which means Legaacy
console Redirection is enabled for Legacy OS.