ACP-4010 User Manual 14
3.1 The Front Panel
The front panel features a lockable door and six LED indicators. The user can close
the door with or without the key with the user-friendly rotary lock. When opening the
door, there is a momentary power switch, two reserved System Reset buttons, an
Alarm Reset button, two reserved 9-pin D-SUB openings, and two dual USB ports.
Their individual functions are described as below.
Figure 3.1 Front view with door closed
Figure 3.2 Front view with door open
3.1.1 Switch, Button and I/O Interfaces
Momentary Power switch: Press this switch to turn the system power on or off.
Please use system shutdown or press this switch for few seconds to turn off the sys-
tem ATX power.
System Reset button: Press this button to reboot the system.
Alarm Reset button: Whenever a fault occurs in the system (e.g., fan failure or the
chassis is overheated), the audible alarm will be activated. Pressing this button will
stop the alarm from beeping.
9-pin D-SUB openings: For connecting COM port devices.
Dual USB ports: For connecting a wide range of USB devices for data transfer,
backup or input.