Advance SC901 handleiding
Handleiding
Je bekijkt pagina 24 van 86

24Service Manual – SC901 20 - Wheel System, Traction
4-2 Hardware Failsafe
Description Drive motor amperage exceeded the controller’s capacity.
Setting
Conditions
When Monitored
Always
Possible Causes
While a short circuit may be the root cause, the drive controller is likely damaged as
a result of uncontrolled amperage.
Initial Action
Clear any cause for a motor short circuit. If the error persists, replace the drive
controller.
Troubleshooting Steps
4-3 EEPROM Fault
4-4 Power Section Fault
Description Internal drive controller fault.
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action
Disconnect the battery to perform a full power-cycle of the machine. If the error
persists, replace the drive controller.
Troubleshooting Steps
Bekijk gratis de handleiding van Advance SC901, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.