22Service Manual – SC901 20 - Wheel System, Traction
3-1 Procedure/Wiring Fault
3-5 High Pedal Disable Fault
Description The throttle was commanded to be active at or before KSI activation.
Setting
Conditions
The 3-1 error is set if the 3-5 error persists for more than 10
seconds.
When Monitored
Boot up
Possible Causes Faulty potentiometer and/or built-in centering springs
Initial Action Make sure the drive paddle is in the neutral position, and key-cycle the machine.
Troubleshooting Steps
3-2 Brake On Fault
3-4 Brake O Fault
Description
The internal driver (transistor) for the brake output has failed in the closed condition
(shorted, Brake On Fault), or the open condition (open circuit, Brake O󰀨 Fault). Note
that the “On” and “O󰀨” refer to the driver, not the output of the brake circuit, which is
inverted.
Setting
Conditions
The drive controller has detected an internal error with its
driver output.
When Monitored
Always
Possible Causes Faulty drive controller
Initial Action
Disconnect the battery to perform a full power-cycle of the machine. If the error
persists, replace the drive controller.
Troubleshooting Steps