Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 37
CHEMICAL RATE BIAS – This funcon allows a ne tuning of the detergent rao.
• NONE
• +10% MORE CHEMICAL
• -10% LESS CHEMICAL
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.
RESTORE DEFAULTS - This funcon is used to reset all sengs to factory default values. If this is done, the next me the
key is turned on, it will act as though a new controller has been installed and “force” you to set the mandatory program
opons before the machine will operate normally.
• NO
• YES
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.
DISPLAY REV LEVEL – Used to display the soware revision.
This is not a seng that can be changed. Aer viewing the revision value, press the scrub on/o switch to return to the
main menu.
FAULT RECALL - This funcon is used by a technician to check for “historical codes” and clear them. If no fault code is
present, the display should show a dash symbol ( - ). If the soluon on/o buon is pressed in the Fault Recall submenu,
the fault history shall be erased. Press the scrub on/o switch to return to the main menu.
FAULT DETECTION - Normally, the Main Machine Controller will perform checks of the electrical system during operaon.
If a fault occurs in a parcular system, that system (and possibly others) will be shut down. This can make troubleshoot-
ing the system dicult. This opon will allow service personnel to disable some of the fault detecon checks to facilitate
troubleshoong. This will not disable the over-current protecon on any of the systems.
• ENABLED
• DISABLED
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.

Bekijk gratis de handleiding van Advance SC750, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAdvance
ModelSC750
CategorieBoenmachine
TaalNederlands
Grootte85385 MB