GENERAL MACHINE TROUBLESHOOTING
Problem Possible Cause Remedy
Poor water pick-up Recovery tank full Empty recovery tank
Recovery tank drain hose leak Secure drain hose cap or replace
Recovery tank cover gasket leak Replace gasket / Seat cover properly
Debris caught in vacuum shoes Clean vacuum shoes
Vacuum hose clogged Remove debris
Foam lter cover not seated Seat cover properly
Poor extracting performance Worn brushes Rotate or replace brushes
Wrong cleaning chemical Consult Advance
Moving machine too fast Slow down
Inadequate solution ow or no
solution
Solution tank empty Fill solution tank
Solution lines, valves, lter, or spray jets clogged Flush lines and clean solution lter & spray jets
Solution control valve is in closed position Place control valve handle in open position
Solution solenoid valves Clean or replace valves
Machine does not run Emergency stop switch tripped Reconnect battery connectors
Operator seat safety switch Check for open circuit and replace
Main system controller
Check for error fault codes (see service manual)
Tripped 10 Amp circuit breaker Check for electrical short circuit & reset
No FWD/REV wheel drive
Drive system speed controller
Check for error fault codes (see service manual)
Tripped 70 Amp circuit breaker
Check for drive motor overload
Emergency stop switch tripped Reconnect battery connectors
Vacuum shuts off and display
shows Recovery Tank FULL
Indicator (E12) when recovery tank
is not full
Plugged vacuum hose(s) Clear debris
Vacuuming large amounts of water at a high travel
speed
Slow down or disable auto shut-off feature
(see service manual)
Poor Sweeping Performance Debris Hopper Full Empty and clean hopper
Brushes worn Replace brushes
Bristles have taken a set Rotate brushes
No Detergent Flow Empty detergent cartridge Fill detergent cartridge
Plugged or kinked detergent ow line Purge system, straighten lines to remove any kinks
Dry seal cap on detergent cartridge not sealed Reseat dry seal cap
Detergent pump wiring disconnected or backwards Connect or reconnect wiring