Mega QA Go Operating Instructions
Dimmer Curve:
This is used to set the dimming curve used with DMX mode. See page 30 for the dimming curves chart.
1. Plug the xture in and press the MODE button until “d.XXX” is dis- played. “XXX” represents the
current displayed DMX address.
2. Press the SET UP button until “dr-X” is displayed. “X” represents the displayed dimmer curve (0-4).
0 - Standard
1 - Stage
2 - TV
3 - Architectural
4 - Theatre
3. Press the UP or DOWN buttons to scroll through and select your desired dimming curve.
Activate IR Sensor:
This function is used to activate and deactivate the IR sensor. When this function is activated you can
control the xture using the UC IR, or Airstream IR App. Please see page 16 for controls and functions.
1. Plug the xture in and press the MODE button until “dXX” is dis- played. “XX” represents either “on”
or “oFF”.
2. Press the SET UP button until “IrXX” is displayed. “XX” represents either “on” or “oF”.
3. Press the UP or DOWN buttons to either activate the remote function (On) or deactivate it (Off).
Default Running Mode:
This is a default running mode. When this mode is activated all modes will return to their default settings.
1. Plug the xture in and press the MODE button until “dXX” is dis- played. “XX” represents either “on”
or “oFF”.
2. Press the SET UP button until “dEFA” is displayed.
3. Press the UP and DOWN buttons simultaneously. Press the MODE button to exit.
Primary-Secondary Conguration:
This function will allows you to link units together to run in a Primary-Secondary set-up. In a Primary-
Secondary set-up one unit will act as the control- ling unit and the others will react to the controlling
units built-in programs. Any unit can act as a Primary or as a Secondary however, only one unit can be
programmed to act as the “Primary.”
Primary-Secondary Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data cables
to link your units together. Remember that the Male XLR connector is the input and the Female XLR
connector is the output. The rst unit in the chain (Primary) will use the female XLR connector only.
The last unit in the chain will use the male XLR connector only.
2. Connect the rst “Secondary” unit to the “Primary.”
3. Set the “Primary” unit to your desired mode of operation. Set the “Secondary” unit(s) to the DMX
address setting of 001.The “Secondary” unit(s) will now follow the “Primary”.