CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE
FIXTURE’S LENS WHILE PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit High Pressure Limit Steady/Hold Time
1.65 psi (11.4 KPa) 1.70 psi (11.7 KPa) 3 sec
IP TEST PARAMETERS
Following any repair or maintenance procedure that requires disassembly of the fixture, use
ADJ’s Hydro IP Tester to confirm the IP integrity of the fixture. The air valve is located on the back
panel next to the display screen, as shown in the diagram below. Please contact ADJ Service for
information regarding the ADJ Hydro IP Tester, or visit the product information page online at:
https://www.adj.com/hydro-ip-tester
DE-HUMIDIFICATION: IP65 fixtures operating in high-humidity environments may experience resid-
ual fogging or condensation. Such fogging will not damage the fixture, and can be removed using
the following procedure: position the unit with the air valve pointing upwards, then open the air valve
and run the unit for 1-2 hours after reaching operating temperature. Then, while the fixture is still hot,
re-install the air valve and allow the unit to cool down. Please note that this procedure should be per-
formed in a dry, air-conditioned environment. Avoid additional fogging by drying the fixture completely
before placing into a road case.
11.. UUppppeerr CCoovveerr
33.. BBoottttoomm CCoovveerr
22.. EEnndd CCoovveerr
MODE
SETUP
UP
DOWN
AAiirr VVaallvvee