SETUP
Setup ETHERNET SETTINGS
IP SETTINGS
Custom IP Address
It lets you assign a custom “IP Address” according to the control unit used.
Custom IP Mask
It lets you assign a custom “IP Mask” according to the control unit used.
Setup ETHERNET SETTINGS
ArtNET SETTINGS
NET
It lets you assign the “Net” parameter (Valid values between 0 and 127).
SUBNET
It lets you assign the “Subnet” parameter (Valid values between 0 and 15).
UNIVERSE
It lets you assign the “Universe” parameter (Valid values between 0 to 15).
Setup ETHERNET SETTINGS
ArtNet to DMX
ENABLEMENT
Disabled (default setting) - The transmission data from Art-Net to DMX output is disabled.
Enabled on primary It activates the data transmission from Art-Net to the DMX output. The fixture works as an
Ethernet/DMX converter so the first fixture receive the ArtNet signal then it transfer the DMX 512 signal to the others units
connected in chain.
UNIVERSE
It let you assign the DMX “Universe” parameter (Valid values between 0 and 015).
Setup ETHERNET SETTINGS
sACN SETTINGS
UNIVERSE
It let you assign the DMX “Universe” parameter (Valid values between 0 and 63999).
Setup DISPLAY SETTINGS
It lets you activate (ON) display brightness reduction after about 30 seconds in idle status. Select OFF to turn off or
disable this option.