EURODIM TWIN TECH
Page 22 sur 92
− DMX A/B present: Yes;
• Yes: DMX signal reception detected
• No: DMX signal reception missing.
− Patch A/B (see "PATCH" menu):
• Yes: the addressing filled-in in each patch at the circuits is not in ascending order,
• No: the addressing filled-in in each patch at the circuits is in ascending order,
e.g. 1, 2, 3, 4, ..., 128 where 32 modules of four circuits are present in the cabinet.
− DMX A/B fail: action implemented in the absence of an DMX A/B signal (see "Priority/DMX
fail" menu), three actions are possible:
• "last value": the last values received to control the circuits are used on a permanent basis as
long as the DMX signal is missing,
• "cue 0:" the DMX signal channel values are replaced by the content of cue 0 with a fade time
of cue 0 and will be played as long as the DMX signal is missing,
• "black": the control value of each circuit fades to black in five seconds.
When the DMX signal is present again, we return to the DMX values with a five-second fade.