ADB Eurodim Twin Tech handleiding

96 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 24 van 96
EURODIM TWIN TECH
Page 22 sur 92
DMX A/B present: Yes;
Yes: DMX signal reception detected
No: DMX signal reception missing.
Patch A/B (see "PATCH" menu):
Yes: the addressing filled-in in each patch at the circuits is not in ascending order,
No: the addressing filled-in in each patch at the circuits is in ascending order,
e.g. 1, 2, 3, 4, ..., 128 where 32 modules of four circuits are present in the cabinet.
DMX A/B fail: action implemented in the absence of an DMX A/B signal (see "Priority/DMX
fail" menu), three actions are possible:
"last value": the last values received to control the circuits are used on a permanent basis as
long as the DMX signal is missing,
"cue 0:" the DMX signal channel values are replaced by the content of cue 0 with a fade time
of cue 0 and will be played as long as the DMX signal is missing,
"black": the control value of each circuit fades to black in five seconds.
When the DMX signal is present again, we return to the DMX values with a five-second fade.

Bekijk gratis de handleiding van ADB Eurodim Twin Tech, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkADB
ModelEurodim Twin Tech
CategorieVerlichting
TaalNederlands
Grootte19177 MB