Page 14 sur 92
If one controller is functional and inserted into the slot at the bottom, the cabinet will work but the
human interface will not be able to present the modules or diagnostic information modules
3.2 MODULE CONTROL
The selector allows the Controller unit in service to be chosen. It may be set to position 1, A/R or 2.
When a controller is selected (1 or 2), the DMX A, DMX B, ARTNET and sACN signals present at this
controller’s input are used.
The software configuration is HTP (Highest Take Precedence) by default. It is the highest value of the
DMX A, DMX B, ARTNET and sACN inputs (three available universes) and cue played and allocated to a
circuit that is taken into account in order to give the output dimming level.
When the selector is set to A/R, the circuits of each module are controlled according to the following rule:
the highest value amongst the DMX A, DMX B, ARTNET and sACN inputs of the two controllers is taken into
account when controlling this circuit.
Example: Control using DMX A and DMX B inputs
Controller 1
DMX A circuit 1=100%
DMX B circuit 2= 0%
Controller 2
DMX A circuit 1=90%
DMX B circuit 2=100%
Circuit 1=100%
Circuit 2= 100%