Powertrain Product
MA48V2K1
3.0 安全/Safety
3.1 電機超速/Overspeed
在常溫和常濕環境條件下,馬達在1.2倍最高工作轉速空載運行2 min,不得發生機械變形
或發出異常聲響。
Under normal temperature and humidity conditions, the motor runs at 1.2 times the
maximum working speed for 2 minutes with no-load, and no mechanical
deformation or abnormal noise is allowed.
3.2 電機短時過/Short Time Overload
馬達在額定電壓下能承受2.5倍載額定轉矩,持續時間1min,重新啟動後應仍能正常運轉。
The motor can withstand 2.5 times the load rated torque under rated voltage for
1min, and it should still be able to operate normally after restarting.
3.3 絕緣電阻/Insulation Resistance
採用500V/500MΩ兆歐表測量,電機繞組與機殼之間的絕緣電阻>10MΩ
Measured with a 500V/500MΩ megohmmeter, the insulation resistance between the
motor winding and the casing is >10MΩ.
3.4 絕緣介電強/Voltage Withstand Test
電機的繞組與機殼之間應能承受如下耐電壓試驗:
The motor winding and the casing should be able to withstand the following voltage
withstand test:
試驗頻率:AC 50 Hz60 Hz,波形為實際正弦波;
Frequency of AC is 50 Hz or 60 Hz, sine wave form;
試驗設備的容量不小於0.5KVA
Capacity of testing equipment is more than 0.5KVA.
試驗電壓為:1800VAC
Test voltage: 1800VAC.
試驗時間:1s
Testing duration: 1s.