AcuRite Iris 06101 handleiding
Handleiding
Je bekijkt pagina 11 van 24

11
Care and Maintenance
Display Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust,
dirt, and moisture. Clean ventilation ports regularly with a gentle puff of air.
Calibration
The temperature, humidity, and barometric pressure can be calibrated on the display to improve
accuracy. Calibration can improve accuracy when sensor placement or environmental factors
impact the data accuracy.
1. To access calibration mode, press
" "
,
"set",
and
" "
buttons simultaneously for at least
5 seconds.
2. To adjust the currently selected (flashing) item, press and release the " " or " "
buttons to calibrate the data value higher or lower from the actual reading.
3. To save your adjustments, press and release the "set" button to adjust the next preference.
The “
” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
• OUTDOOR TEMPERATURE
• OUTDOOR HUMIDITY
• INDOOR TEMPERATURE
• INDOOR HUMIDITY
• BAROMETRIC PRESSURE
(must be set to MANUAL mode to calibrate)*
*To change from AUTO to MANUAL pressure mode and vice versa, PRESS AND HOLD the
"set" button for at least 10 seconds. The display indicates the current pressure mode selected,
“auto” or “manual”.
After 10 seconds of inactivity, the display will save the adjustments and exit calibration mode.
NOTE: Calibrations will be erased if the display is reset or if batteries are removed.
Bekijk gratis de handleiding van AcuRite Iris 06101, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | AcuRite |
| Model | Iris 06101 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 2791 MB |
