ACR G406-4 handleiding

70 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 60 van 70
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
G406-4 (453-5012)
570-5012 Rev. P Company Confidential 25-62-21 Page 60 of 70
3) Apply a thin coating of non-petroleum based silicone grease, such as GE G-635, to the rubber seal to
facilitate installation and allow the ELT and battery pack to slide together without binding on the rubber
seal.
4) Lay the battery pack and ELT on their sides, such that the two components are aligned, but separated
enough to allow the electrical connections to be made.
5) Connect the ELT lead 8-pin connector to the header on the battery pack circuit board.
6) Connect the power harness 2-pin connector to the recessed connector inside the ELT body.
7) Reset the ELT by toggling the ELT local control switch to “ON” and back to “OFF” after 1-2 seconds.
NOTE: This step is necessary because the ELT will occasionally activate when power is
connected to it in Step 6.
8) Fit the battery pack into place on the ELT, while dressing the wires away from the standoffs to avoid
pinching the wires between the standoffs and battery pack.
9) Turn the battery pack bottom face up to facilitate installing the screws, while securely holding the ELT
and battery pack together.
10) Install the four battery pack retaining screws about half way (i.e., leave them loose).
11) Tighten and torque the screws as shown in Figure 23 Battery Pack Retaining Screw Tightening Pattern.
Torque to 6-8 lb-in (68-90 N•cm).
Figure 23 Battery Pack Retaining Screw Tightening Pattern
12) Perform an ELT self-test as follows:
a) Set the ELT local control switch in the “ON” position. The LED will begin flashing every 3-4
seconds.
b) Return the switch to the “OFF” position after 1-2 seconds. If the ELT is working properly, the LED
will stay on for approximately 1 second and then flash the following expected error codes, which
should be ignored.
1. 1-flash and 3-flash errors, which are generated because the ELT is not installed and
connected to an antenna, etc.
2. A 5-flash error will be indicated if the ELT is programed with a location protocol, and is
generated because the ELT is not connected to the navigation system and receiving position
data.
c) If a 7-flash error code is indicated, there is a problem with the battery or battery connection
wiring. Refer to Table 6 on page 37.

Bekijk gratis de handleiding van ACR G406-4, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkACR
ModelG406-4
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8218 MB