570-5012 Rev. P Company Confidential 25-62-21 Page 56 of 70
a) Connect three suitably supported 9V alkaline batteries together in series.
b) Connect the positive (+) side to Pin 3 of the remote switch connector.
c) Connect the negative () side to aircraft ground, such that the circuit is complete.
d) Check the battery voltage periodically and replace the batteries every two years.
e) Note the alteration in the aircraft logbook.
SUBTASK 25-62-21-450-008
I. Airframe Ground Connections
1) Connect the ground wires to the airframe in accordance with the aircraft manufacturer’s written
instructions or as described in AC 43.13-1, Chapter 11, § 15, as applicable. See Figure 19 Remote
Switch Harness Wiring Diagram on page 53.
SUBTASK 25-62-21-450-009
J. Buzzer Connections
1) Connect the power wire to the buzzer positive (+) terminal.
2) Connect the ground wire to the buzzer negative () terminal.
SUBTASK 25-62-21-450-010
K. Remote Switch Final Installation
1) Insert the harness plug into the remote switch receptacle.
2) Install the remote switch assembly in accordance with SUBTASK 25-62-21-450-002 on page 54.
TASK 25-62-21-410-802
7. ELT Installation
SUBTASK 25-62-21-410-001
A. Installation and Test
1) See Figure 21 ELT Installation Sequence.