SUBTASK 25-62-21-750-001
F. G-Switch Functional Check Item 4
CAUTION: A JUMPER IS REQUIRED TO PERFORM THIS CHECK. DUE TO THE POTENTIAL OF
PHYSICAL DAMAGE IF THE JUMPER IS IMPROPERLY INSTALLED, THIS STEP
SHOULD ONLY BE PERFORMED BY AN EXPERIENCED TECHNICIAN/MECHANIC.
1) Reinstall the battery in accordance with SUBTASK 25-62-21-450-001 on page 59.
NOTE: If tests 5a through 5h are going to be performed, the battery may be temporarily
installed with only two screws, located on a diagonal from each other.
2) Perform this functional check within the first 5 minutes after the hour (UTC), as required by AC
43.13-1, Chapter 12, § 12-22, Note 3.
3) Notify any nearby control tower of your intentions.
4) Install the 151-2012 test plug (receptacle) on the ELT plug or jumper ELT plug Pins 5 and 8.
NOTE: The ELT cannot be activated using this procedure unless Pins 5 and 8 on the ELT
plug are jumpered. See Figure 19 Remote Switch Harness Wiring Diagram on page
53.
5) Verify the ELT switch is in the “OFF” position.
6) Monitor 121.5 MHz on an AM receiver.
7) Activate the ELT by using a rapid forward (i.e., throwing) motion in the direction of the arrow on the
ELT label, followed by a rapid reversing action.
8) Verify activation by listening for the aural sweep tone on the receiver.
9) Reset the ELT by toggling the control switch to the “ON” position and then back to the “OFF”
position.