ACR G406-4 handleiding

70 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 70
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
G406-4 (453-5012)
570-5012 Rev. P Company Confidential 25-62-21 Page 23 of 70
SUBTASK 25-62-21-870-002
B. Electrical
1) Table 3 lists the electrical specifications of the G406-4 ELT.
CRITERIA
PARAMETER
CHARACTERISTIC
Operating Frequencies
406.025 MHz
± 2 KHz (Initial)
± 5 KHz (5 years)
2 parts/10E9 in 100 ms
406.028 MHz, or higher
± 1 KHz
121.5 and 243.0 MHz
± 0.005%
Modulation
406 MHz
Bi-Phase L (G1D)
121.5 and 243.0 MHz
Amplitude Modulation (A3X)
Transmitter Duty Cycle
406 MHz
440 ms (± 1%), or
520 ms (± 1%), every
50 seconds (± 5%)
121.5 and 243.0 MHz
Continuous
Peak Effective Radiated
Power (PERP)
406 MHz
5 W (37 ± 2 dB) PERP, or
EIRP for 24 hrs @ -20° to +55° C
121.5 and 243.0 MHz
Min. 50 mW (17 dBm) PERP for 50
hrs @ -20° to +55° C or 100 mW
EIRP (20 dBm) for 48 hrs @ -20° to
+55° C
Occupied Bandwidth
406 MHz
20 KHz max.
121.5 and 243.0 MHz
25 KHz max.
Spurious Emissions
406 MHz
Per RTCA/DO-204
121.5 and 243.0 MHz
Per CFR Title 47 (FCC), Part 87
Battery
Type of Cell
Lithium Manganese Dioxide
Voltage
12.0
Amp-Hour Rating
10.0
Table 3 Electrical Specifications