Installation Manual I Service and Troubleshooting
23
MP4010-1809
PM TASK DECRIPTION DAILY ANNUAL
Verify that the Steamer is level.
X
Verify the operation of the control panel. When a button is pressed the
display should register the input and a beep should sound.
X
Verify the operation of the indicator lamps.
X
Clean water fill sensors with non abrasive metallic pad. DO NOT use
sandpaper.
X
(AUTO-FILL ONLY) Ensure unit fills with water to the water level line.
X
Lubricate hinges and door latch with a food grade silicon spray
Monthly
Lubricate stand casters
Monthly
Inspect AC power cord for degradation or bare wires. Replace if defective
or suspect
X
Inspect door gasket for cuts and degradation. Replace if damaged. We
suggest replacing once a year.
X
Inspect Steam distribution panel gasket for cuts and degradation. Replace
if damaged. We suggest replacing once a year
X
Inspect and clean steam vent, condensate line fittings and hoses.
X
Inspect the flue for foreign particulate that has fallen inside. Remove any
particulate. Check that the flue has not been pushed in. If the flue has
been pushed in, pull the flue out so that flue opening is at the original
shape.
X
Verify the operation and condition of the igniter probe/flame sense
assembly. Probes should be cleaned with a stainless steel wire brush and/
or emery cloth. A stainless steel knife can also be used or a dollar bill.
Caution: DO NOT use any abrasive that contains
Silica. This will leave a coating on the flame sensor that could cause the
unit not to light. Install Electrode Ignitor Assembly if cleaning doesn’t
work. We recommend replacing every two years.
X
Clean Gas Orifice
X
Inspect the control compartment for foreign particulate and any loose
wiring or connections.
X
Verify that the dynamic operating pressure of the unit is at 5”WC
X
Check Pressure Switch for correct operation. Recommend to replace
every two years.
X
Inspect external and internal water connections and condensate lines for
degradation and leaks. Replace as necessary
X
PREVENTATIVE MAINTENANCE
Note: Accutemp approved service providers should complete any tasks involving access to gas
and electrical systems.