AccuTemp Evolution E62401E060 handleiding
Handleiding
Je bekijkt pagina 14 van 30

Installation Manual I Installation
13
MP4053-2006
3.7 Electrical Requirements and Notices
The electrical voltage requirement is listed on the data plate that is located on the lower left side panel.
All AccuTemp Evolution Electric Steamers are supplied with a power cord and plug that must be connected to the
specified receptacle, see below for reference.
Make sure the voltage is within 10% of the voltage listed on the steamer data plate.
Connection to any other voltage not identified on the data plate will cause damage to the components and is not covered under
warranty.
Grounding provides a path for electric current to reduce risk of shock.
This product is equipped with a power cord having a grounding plug. If plug is removed or hard wired, UL approval is lost.
The plug must be plugged into a receptacle that is properly installed and grounded in accordance with all National, State and
local electrical codes or in the absence of local electrical codes with the National Electric Code, ANSI/NFPA 70, or the Canadian
Code, CSA C22.2 as applicable.
Under no circumstances shall the plugs grounding prong be cut or bent to fit a receptacle other than the one specified.
Do not use any adapters.
Any in-field modification made that bypass the safety features of this appliance will result in serious injury or death. DO NOT
DIRECT WIRE THIS APPLIANCE.
Any in-field modifications made without written authorization from AccuTemp Products, Inc. will void all written and oral
warranties.
ELECTRICAL SPECIFICATIONS
Notes:
1. Allow 3” between fryer, ranges, and other
hot surfaces.
2. 5’ power cord supplied with single or 3
phase.
3. For use on individual branch circuit only.
4. Do not connect to a circuit operating at
more than 150V to ground.
5. Dimensions outside brackets are inches,
in brackets are millimeters.
6. Each unit equipped with 3/4” male garden
hose connector
7. Each unit equipped with 3/4” barbed drain
line connector
8. DO NOT plumb a single drain line
between the 2 units. Each
unit must have a separate drain line.
E6 TABLETOP CONNECTED EVOLUTION
™
6 Pan, Electric Boiler-free Convection
Countertop Steamer
MM4216-2001
AccuTemp Products, Inc.
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
30.39
771.91
23.26
590.88
4.00
101.60
23.63
600.20
2.85
72.42
30.48
774.22
40.95
1040.13
15.53
394.49
8.56
217.42
1.99
50.47
4.04
102.54
11.61
294.77
6.29
159.87
3/4 IN. BARB
FOR OPEN-GAP
DRAIN
3/4 IN.
MGH WATER
CONNECTION
Steamer Model “E” Specifi cations
Model #
E62081E060 E62083E100 E62083E150 E62301E070 E62401E060 E62403E110 E62403E130 E64005E110 E64803E140
Volts AC
208 208 208 230 240 208 240 240
380 400 41 5
440 480
Phase
1 3 3 1 1 3 3 3 3
Amps
29 28 42 32 25 22 26 32 14 14 15 16 17
Breaker Size
30 amp 30 amp 50 amp 50 amp 30 amp 30 amp 50 amp 20 amp 20 amp
Watts (kW)
6 10 15 7 6 8 11 13 9 10 11 12 14
NEMA Plug
L6-30P L15-30P 15-50P IEC 60309-2
220/250V
L6-30P L15-30P 15-50P IEC 60309-2
220/380-240/415V
L16-20P
®
E
VOLUTION
BOILER-FREE STEAMER
AccuTemp product may be covered by one or more US Patents. See www.accutempip.net
CONNECTED
CONNECTIONLESS
E6 TABLETOP CONNECTIONLESS EVOLUTION
™
6 Pan, Electric Boiler-free Convection
Connectionless Countertop Steamer
MM4221-2001
AccuTemp Products, Inc.
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
Steamer Model “D” Specifi cations
Model #
E62081D060 E62083D100 E62083D150 E62401D060 E62403D110 E62403D130 E62301D070 E64005D110 E64803D140
Volts AC
208 208 208 240 208 240 240 230
380 400 41 5
440 480
Phase
1 3 3 1 3 3 1 3 3
Amps
29 28 42 25 22 26 32 32 14 14 15 16 17
Breaker Size
30 amp 30 amp 50 amp 30 amp 30 amp 50 amp 50 amp 20 amp 20 amp
Watts (kW)
6 10 15 6 8 11 13 7 9 10 11 12 14
NEMA Plug
L6-30P L15-30P 15-50P L6-30P L15-30P 15-50P IEC 60309-2
220/250V
IEC 60309-2
220/380-240/415V
L16-20P
Notes:
1. Allow 3” between fryer, ranges, and other hot surfaces.
2. 5’ power cord supplied with single or 3 phase.
3. For use on individual branch circuit only.
4. Do not connect to a circuit operating at more than 150V to ground.
5. Dimensions outside brackets are inches, in brackets are millimeters.
®
E
VOLUTION
BOILER-FREE STEAMER
AccuTemp product may be covered by one or more US Patents. See www.accutempip.net
Bekijk gratis de handleiding van AccuTemp Evolution E62401E060, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | AccuTemp |
Model | Evolution E62401E060 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 8156 MB |