Abus Smartvest Pro APP45000 handleiding
Handleiding
Je bekijkt pagina 42 van 116

| 42
Alarm muting function (hush
mode)
If the detector is in the alarm state, the acoustic alarm can be
deactivated for 10 minutes by pressing the Test button.
If the muting function is active, the red LED flashes every
8 seconds.
If smoke is still detected in the smoke measurement chamber after
the ten-minute muting period, the acoustic alarm will sound
again.
8.7 Alarm tone overview
Status
LED
Alarm tone
Status: normal
Every 40 seconds
No tone
Alarm Status: Smoke
Simultaneously at short
intervals
Alarm tone 0.5 s – pause 0.5 s –
Alarm tone 0.5 s – pause 0.5 s –
Alarm tone 0.5s – pause 1.5 s
Alarm Status: Heat
Simultaneously at short
intervals
Alarm tone 0.2 s – pause 0.1 s
Status: Low Batterie
At the same time as the tone
Every 40 seconds
Dirty smoke chamber
Not at the same time as the
tone
Every 40 seconds
Alarm triggered by other smoke
detectors
Not at the same time as the
tone
Alarm tone – alarm tone - pause
1.2 s
Test alarm triggered by other
smoke detectors
Simultaneously at short
intervals
Alarm tone – alarm tone - pause
1.2 s