Abus Smartvest Pro APP45000 handleiding

116 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 36 van 116
| 36
Do not cover the device.
Do not paint over the device or cover it with wallpaper.
Do not, on any account, open or repair the device. Failure to observe this
instruction will invalidate the warranty.
Do not use the device if it has been dropped or damaged in any other way.
Functional principle and features
The smoke detector does not detect gas, steam, re or ames.
People with impaired hearing may not be able to hear the alarm. Alarms with
additional optical signalling are available for such cases.
Particularly high electromagnetic radiation could impair the function of the
detector. For this reason, do not install the detector near magnets or devices
which produce electromagnetic radiation.
The smoke detector operates in accordance with the optical principle
(photoelectric reection) and features a measurement chamber in which
inltrating smoke particles are measured.
If the alarm threshold is exceeded, a loud acoustic alarm sounds. The smoke
detector also has a heat detector that triggers an alarm if a threshold value is
exceeded.
The alarm is switched o as soon as the measurement chamber is free of smoke
again and/or the temperature has fallen back to a normal level.
What should you do in the event of a false alarm?
Possible reasons for a false alarm are: Welding and cutting work, soldering and other
high-temperature work, sawing and grinding, dust from construction work or cleaning,
extreme electromagnetic effects, and temperature fluctuations which lead to
condensation of the humidity in the detector.
If work which could cause false alarms is being carried out near the detector, the detector should
be covered or removed temporarily. After this work is completed, however, it is essential
to restore and test the original functionality.
Cleaning
According to German application standard DIN 14676, the functionality of every installed
smoke detector must be regularly tested and ensured by maintenance measures.
This consists of an inspection at least once every 12 ± 3 months including maintenance
and function checks of the warning signals.
The measures and results must be documented accordingly.
Dusty detectors must be cleaned. You can clean dust from the air vents of the
detector using a vacuum cleaner or compressed air.
If necessary, you can remove the dust with a brush.