Table of Parameters 3.2
30
Signaling
Line reversal indication for call in progress Function No.: -
Select call in progress signaling by telephone line polarity reversal. There is
voltage of reversed polarity on the telephone line during the whole call.
Setting options: YES/NO
Default setting: NO
Tariff pulse when call starts/ends Function No.: -
Signaling of call start or end by tariff pulse.
Setting options: None -EasyGate doesn't send tariff pulse as signaling
of call start/end.
Call end -EasyGate sends tariff pulse when call ends.
Call start -EasyGate sends tariff pulse when call
starts.
Call start and end -EasyGate sends tariff pulse when
call starts and ends too.
Default setting: None
Tariff pulse frequency Function No.: -
Tariff pulse frequency setting.
Setting options: 16 kHz -EasyGate transmits 16 kHz tariff pulses
12 kHz -EasyGate transmits 12 kHz tariff pulses
Default setting: 16 kHz
Tone settings
Dial tone – Double frequency tone[Hz] Function No.: -
Set for double frequency tones
Setting options: YES/NO
Default setting: NO
Dial tone – frequency [Hz] Function No.: -
Setting of frequency/frequencies of dial tone.
Setting options: 5-1275 Hz
Setting step: 5 Hz
Default setting: 425 Hz

Bekijk gratis de handleiding van 2N Telecommunications EasyGate, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

Merk2N Telecommunications
ModelEasyGate
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6292 MB

Caratteristiche Prodotto

Markt positioneringBedrijf
Ingangsspanning12 V
Soort apparaatGateway voor mobiele netwerken
DatanetwerkGPRS, GSM
GSM bands ondersteund850,900,1800,1900 MHz