Table of Parameters
3.2
33
Volumes
Transmission volume Function No.: 190
Volume setting for GSM transmission with a 4 dB step.
Setting options: 1-5
Setting step: 1
Default setting: 3 = medium volume level
Reception volume Function No.: 191
Volume setting for GSM reception with a 4 dB step.
Setting options: 1-5
Setting step: 1
Default setting: 3 = medium volume level
Ringing signal settings
Ringing signal – frequency [Hz] Function No.: 140
Ringing signal frequency setting.
Setting options: 25 / 50 Hz-EasyGate rings with 50 or 25 Hz on FXS
interface
Default setting: 50 Hz
Ringing signal - cadence Function No.: 141
Ringing signal cadency setting.
Setting options: 1000/4000 ms (0) - 1 s ring, 4 s pause
400/200/400/2000 ms (1)- 400ms ring, 200ms pause,
400ms ring, 2s pause
1500/3500 ms (2) - 1,5 s ring, 3,5 s pause
2000/4000 ms (3) - 2 s ring, 4 s pause
Default setting: 1000/4000 ms
CLI transmitting Function No.: 148
Set this item to enable/disable identification of a telephone line calling from a
mobile network. The function can be enabled if you have a device on your
telephone line that is capable of receiving FSK according to ETSI standards.
Setting options: Disable (0) - EasyGate does not transmit the CLI.
FSK during ringing (1) -EasyGate transmits the FSK-
based CLI according to the ETSI EN 300 659 standard
(transmission during ringing).
Default setting: Disable

Bekijk gratis de handleiding van 2N Telecommunications EasyGate Pro, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

Merk2N Telecommunications
ModelEasyGate Pro
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8603 MB

Caratteristiche Prodotto

Ingebouwd displayNee
USB-poortJa
Markt positioneringBedrijf
Aantal USB 2.0-poorten1
Ingangsspanning100 - 240 V