2N Telecommunications 932081E handleiding

Handleiding

Je bekijkt pagina 84 van 110
2N TELEKOMUNIKACE a.s., www.2n.cz 84/110
Induction Loop
2N Induction Loop
®
(Part No. 9159050 Induction loop amplifier for 2N Helios
intercom, Part No. 9159054 Induction loop amplifier without Helios accessory, Part
No. 9159051 External induction loop for wall mounting, Part No. 9159052 - 12 V DC
power adapter) is part of sound system installations for hearing impaired persons that
are equipped with a special hearing aid capable of receiving reproduced sound via a
magnetic field receiver. The system is defined by the IEC 60118-4 standard.
Installation:
The induction loop amplifier can be wall mounted with the use of an internal induction
loop where a signal covering is requested. Outdoor use is possible thanks to the IP65
covering. A four-wire cable of the length of one meter is mounted to the supplied
product for easier connection to the intercom. In the cable are two wires for 12 V DC
supply and two wires for signal input, the wires are connected into interconnection
connector. If you shorten the cable, follow the colour marking.
Before wall mounting run the cable through the hole that you have prepared. Then
mark two mounting holes on the wall, through the amplifier front. Remove the
amplifier and drill the mounting holes. Use the plugs and screws included in the
delivery. Use a drill of the diameter of 6 mm. After fastening, cover the screws with
the blanks supplied.
Use the supplied connectors to connect the amplifier to the intercom and power
supply. The A connector is connected to the amplifier four-wire cable. Insert a special
intercom-connecting cable supplied with the amplifier and 12 V power supply outlets
to the B connector. Connect the special cable to the intercom and connect the power
supply to the mains. You can place the mated A and B connectors into the 2N® Helios
cover. The connectors help you connect stripped cables. Open the connector by
pushing a thin screwdriver onto the white spots at its front and close the connector by
sliding the movable part through a side gap.
Finally, test the amplifier function using a suitable receiver for hearing impaired
persons or magnetic field communication tester. No other settings are required.

Bekijk gratis de handleiding van 2N Telecommunications 932081E, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

Merk2N Telecommunications
Model932081E
CategorieNiet gecategoriseerd
TaalNederlands
Grootte18445 MB

Caratteristiche Prodotto

Kleur van het productGrijs
Type stroombronDC
Aantal1
Bedrijfsspanning (max)12 V
Stroomverbruik (max)0.23 A